Smaller cremators incinerators
Smaller cremators that will run diesel and will be capable of doing all the other dogs/cats/pets that we have. We only cremate pets individually so this is what we require. Have your company as member of Markis Hospital waste management group as planer or supplier, contractor of solutions or operating partners of the solution of hospital waste management in the projects we are developing, starting with Larissa and Volos. Members of Markis waste management group will also have the possibility to provide training and technical services to the health sector of Greece and other countries via the TSC which we plan to make the same time in Larissa (enclosed diagram indicates the role of each party joining Markis waste management group). ● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power consumption to be stated ● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste ● Solid waste reduction in range of 90-97% ( should be routinely achieved) 1. – 2 medical waste autoclaves 350ltr and 100ltr 2. – 1 medical waste shredder 3. – 3 medical macerators 4. – 27 Waste transfer trolleys.
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards 1) Bidder or Manufacturer ISO 9001 Certified 2) Respecting international emission standards Electrical characteristics 3) A 230V, 60Hz single-phase electrical source. 4) Protections against over-voltage and over-current line conditions. 5) Compliance with applicable Ghanaian standards and regulations. Operational characteristics 6) Two-stage incineration with dual chamber combustion 7) Burn rate: 15 – 20 Kg/h 8) Capacity: not less than 130 L 9) Concentrations of most pollutants in stack gases below detection limits 10) Diesel fuel 11) Electronic system control 12) Easy to operate and minimal training 13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application For incineration, general and pathological Capacity 100 C 120 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system flame detector Air fan Complete with safety features, flame failure Diesel fired fuel injector type Flange mounted Blower Provided. 3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type 3.3 Secondary chamber
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application For incineration, general and pathological Capacity 100 C 120 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system flame detector Air fan Complete with safety features, flame failure Diesel fired fuel injector type Flange mounted Blower Provided. 3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type 3.3 Secondary chamber
Incinerador de desechos médicos de aire controlado diseñado para la incineración de desechos biomédicos
Incinerador de desechos médicos de aire controlado diseñado para la incineración de desechos biomédicos generados en un centro de procesamiento de sangre. Los desechos a tratar incluyen principalmente biorresiduos (es decir, fluidos corporales), desechos infecciosos y peligrosos como jeringas, agujas y otros desechos médicos (es decir, cauchos de silicona, plástico, textiles, papeles, paquetes, etc.) Especificaciones operativas Especificaciones físicas Volumen de la cámara de combustión (m3) 8.80m3 Velocidad de combustión* hasta 1500 kg por hora Consumo medio de combustible 65 kg por hora o más (7 quemadores diesel) Temperatura operacional 850 – 1320 ° C Retención de gas en cámara secundaria Gran cámara secundaria Monitoreo de temperatura sí Residuo medio de cenizas (%) 3% Dispositivo termostático sí Depósito de humos diesel 1000l Depurador de gas Venture Sistema de alimentación de ariete hidráulico Incinerador grande con motor diésel Especificación mínima requerida Estándares 1) Licitante o fabricante con certificación ISO 9001 2) Respetando…
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Brand ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line Requirements.5) Compliance with applicable Ghanaian standards and regulations.Operational characteristics6) Two-stage incineration with dual chamber combustion7) Burn rate: 15 – 20 Kg/h8) Ability: not less than 130 L9) Concentrations of most pollutants in stack gases under detection limits10) Diesel fuel11) Electronic Machine control12) Easy to operate and minimal training13) Any accessory or dedicated Apparatus necessary to the proper functioning and utilization of the equipment included
mit Dieselöl befeuerte Verbrennungsanlage für medizinische Abfälle
Hochtemperatur-Abfallverbrennungsanlage Modell D. MB 750XL Verbrennungsrate-150 kg / Stunde Mindestgewicht (kg) -4000 kg Sekundärkammer (Doppelkammer mit Nachverbrennung) Gasretentionszeit 2 Sekunden Kraftstoff-Diesel-Netzteil für Steuerbox 220V-240, einfach Phase 50-60Hz Minimale Betriebstemperatur 1200 oC Einjähriges Ersatzteilpaket für vollständige Wartbarkeit 10 m Schlauch Rohr. 1100-Liter-Kraftstofftank + Rohrsystem Containerisiert (der Container dient als Gehäuse) Zusätzliche Kaminverlängerung 1 Meter hoch Ein (1) Jahr Garantie. Verbrennungsanlage von 20 kg: 03 Einheiten Elektrisch gesteuerte Verbrennungsanlage. Zweikammerverbrennungsanlage mit einer Kapazität von 20 kg / Stunde. Verbrennungsanlage mit geringen Wartungs- und Betriebskosten; Ausgestattet mit einem automatischen Bedienfeld und einfach zu bedienen elektromagnetische Verriegelung der Tür. Eine Hauptabfallreduktionskammer von 900 ° C. Eine postsekundäre Brennkammer aus Gasen, die in der Primärkammer erzeugt werden mindestens 1100 ° C. Kohlenstoffrückstände in Asche von weniger als 5 Gew .-% gemäß der europäischen Richtlinie 2000/76 / EG. Mit feuerfester Auskleidung aus hochwertigeren Materialien 1 / Kosten für eine Verbrennungsanlage für medizinische Abfälle mit 200 kg…
Fourniture, installation et mise en service des INCINÉRATEURS DIESEL
Fourniture, installation et mise en service des INCINÉRATEURS DIESEL Incinérateur de déchets médicaux, 100 à 120 kg / h Application Pour incinération, générale et pathologique Capacité 100 C Vitesse de combustion de 120 kg / h Taper Type à deux chambres de combustion; air de combustion primaire et secondaire, contrôlé / forcé avec une unité de lavage des gaz de combustion Temps de fonctionnement Minimum 8 heures par jour Température de fonctionnement De 850 0C à 1200 0C, à commande automatique Cendres résiduelles 5 à 10% Construction Fabriqué en acier doux ou aluminisé robuste Ou équivalent et équivalent approuvé Matériel d’isolation Revêtement en matériau réfractaire similaire ou égal au calcium Combinaison de silicate et de face chaude de maçonnerie résistante Construction interne Type de foyer fixe complet avec grilles, fond concave et porte de chargement, revêtu de matériau réfractaire Porte de chargement Convient pour le chargement manuel des déchets et…
pet incinerator deisel
pet incinerator deisel is small-middle size incinerator for pet cremation and the fuel type is diesel oil. we sale the model TS50 with 560 liter combustion chamber, for small and big pet cremation.