Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application For incineration, general and pathological Capacity 100 C 120 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system flame detector Air fan Complete with safety features, flame failure Diesel fired fuel injector type Flange mounted Blower Provided. 3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type 3.3 Secondary chamber
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS
Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application For incineration, general and pathological Capacity 100 C 120 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system flame detector Air fan Complete with safety features, flame failure Diesel fired fuel injector type Flange mounted Blower Provided. 3 phase for supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type 3.3 Secondary chamber
MEDICAL WASTE INCINERATOR (50 C 60kg/hr)
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity 50 C 60 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% 3.2 Primary Chamber Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure, Diesel fired fuel injector type and Flange mounted Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures Above 850 0C, controlled electronically Gas residue or retention Time > 2 second at minimum 850 0C Secondary Burner Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system, Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type. Flange mounted Ejector Provided, Venturi type, for cooling the flue gases Combustion Air Fan Provided for supplying combustion and creating a negative drift and turbulences Temperature Maximum 1600 0C
MEDICAL WASTE INCINERATOR (50 C 60kg/hr)
Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity 50 C 60 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% 3.2 Primary Chamber Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickwork Internal Construction Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges. Door Lock Automatic, Electric type Ash removal door Provided, for removing resultant bottom ash leftovers from the Primary chamber Gratings Provided Loading Manual loading of waste Primary Burner Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure, Diesel fired fuel injector type and Flange mounted Blower Provided. For supplying excess combustion air through the distribution system with speed control system Temperature Minimum exit 850 0C Observation port To be provided with protective glass type Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures Above 850 0C, controlled electronically Gas residue or retention Time > 2 second at minimum 850 0C Secondary Burner Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system, Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type. Flange mounted Ejector Provided, Venturi type, for cooling the flue gases Combustion Air Fan Provided for supplying combustion and creating a negative drift and turbulences Temperature Maximum 1600 0C
Suministro de Inclinadores para Proyecto de Terminal Nacional de Llegada Provisional
Servicios CMC para inclinadores durante 3 años, incluidos todos los repuestos, consumibles, mano de obra calificada, herramientas y aparejos, todo completo. Según el alcance adjunto como anexo Diseño, fabricación, suministro, entrega al sitio, instalación, prueba y puesta en servicio de todos los inclinadores de pasajeros resistentes a la intemperie de acuerdo con el alcance y las especificaciones generales mencionadas en el anexo. Incinerador Spesifikasi 100 kg / mermelada Material de Spesifikasi dan Daftar Capacidad de potencia dimensional Nama Barang : INCINERADOR Tipo / Modelo : PWR-INC-KMN 10 Kapasitas: 100kg / Mermelada (1 m3) Largo : 288 cm Ancho : 147 cm Altura : 163 cm Altura de la chimenea estándar: 700 cm PESO TOTAL: 8000 kg Panel – temporizador : Alarma automática digital incluida Refinamiento : Pintura resistente al calor Depósito de combustible : 200 litros Elemento de revestimiento de acero: 3-8 mm Quemador Banyaknya: 2 piezas Soplador Banyaknya :…
pet cremation equipment
a.) incinerator for waste. VS pet cremation equipment for animals b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns. c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation equipment is personal business more. f.) waste incinerator with small-large scale capacity. VS pet cremation equipment with regual pet size or weight g.) waste incinerator feeding door small or big. VS pet cremation equipment feeding door match with pet size h.) waste material with or without fat. VS pet body with fat. i.) waste incinerator with or without exchange feeding door. VS pet cremation equipment better with exchange feeding door.
pet crematory
Waste Incinerator vs pet crematory a.) incinerator for waste. VS cremator for animalsanimal-cremation b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns.pet-cremation-urns c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation is personal business more.265_00066_23SEPT.jpg f.) waste incinerator with small-large scale capacity. VS pet cremation with regual pet size or weight g.) waste incinerator feeding door small or big. VS pet cremator feeding door match with pet size h.) waste material with or without fat. VS pet body with fat.cremation-ash i.) waste incinerator with or without exchange feeding door. VS pet cremator better with exchange feeding door.pet-cremation-in-incinerator-chamber
Поставка инклинаторов для проекта внутреннего терминала промежуточного прибытия
Услуги CMC для инклинаторов на 3 года, включая все запасные части, расходные материалы, квалифицированную рабочую силу, инструменты и снасти. Согласно Объему, приложенному в Приложении Проектирование, производство, поставка, доставка на объект, установка, тестирование и ввод в эксплуатацию всепогодных пассажирских инклинаторов в соответствии с Объемом и техническими условиями, указанными в Приложении. Инсинератор Spesifikasi 100кг / варенье Описание дан Daftar Material Размеры и мощность Мощность Нама Баранг : ИНСИНЕРАТОР Тип / Модель : PWR-INC-KMN 10 Капаситас: 100 кг / джем (1 м3) Длина : 288 см Ширина : 147 см Высота : 163 см Высота дымохода: 700 см. ОБЩАЯ ВЕС: 8000 кг Панель – таймер : Цифровая автоматическая сигнализация Отделка : Термостойкая краска. Топливный бак : 200 литров Покрывающий элемент из стали: 3-8 мм Горелка Банякня: 2 шт. Банякня воздуходувка : 2 шт. Максимум. Расход топлива: 15-30 литров / джем Максимум. Электрическое потребление : 1100 Вт Бахан Бакар : Керосин / Дизель (солнечная…