Tag Archives: chamber

300 kg incinerator is the model YD-300, oil or gas fuel. the primary chamber is 220 x 110 x 100cm, means 2400 Liters. Model YD-300  Burning Rate 300 kgs/hour Feed Capacity 500 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.48Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 26–48.1 kg/hour Gas Consumption (Natural Gas) 16.1–48.8 m3/hour Internal Dimensions 220 x 110 x 100cm (primary chamber) External Dimensions 260 x 220 x 420cm (without chimney) Temperature Monitor Yes Oil Tank Capacity(if oil fuel) 500 Liters Door Opening 90 x 110cm Chimney Length 10.0 Meters Chimney Type Stainless Steel Equipment Gross Weight 8300 kgs Operation Technical Specifications Paimary Chamber Temperature 800℃–1000℃ Secondary Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Burning Efficiency >98% Waste Lower Calorific Power 3000Kcal Items Specification Model…

Read more

we are incinerator medical waste manufacturer. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of small clinics to the more demanding and specialized requirements of large hospitals in their waste management processes. Items/Model YD-30 YD-50 YD-100 YD-150 Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs Primary Chamber (Liters) 360 900 1200 1500 Secondary Chamber (Liters) 200 200 500 500 External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Oil Tank(Liters) 200 300 300 300 Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Chimney (M) 5 5 10 10 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES…

Read more

most of the medical waste diesel incinerator for developing country. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Items/Model YD-30 YD-50 YD-100 YD-150 Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs Primary Chamber (Liters) 360 900 1200 1500 Secondary Chamber (Liters) 200 200 500 500 External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Oil Tank(Liters) 200 300 300 300 Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Chimney (M) 5 5 10 10 Chimney…

Read more

Principle of the infectious waste pyrolysis machine china is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.

we are laboratory incinerator china manufacturer. the laboratory incinerator is small scale incineration equipment for waste from lab. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs Primary Chamber (Liters) 200 200 250 400 Secondary Chamber (Liters) 140 140 140 140 External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200 Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85 Oil Tank(Liters) 50 100 100 150 Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55 Chimney (M) 5 5 5 5 Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Secondary Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Residency Time 2.0 Sec. 2.0 Sec. 2.0…

Read more

Clover Incinerator supply small scale incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour. We are famous small scale incinerator manufacturer and brand, dispatch incinerator products and best services with lower price for customer all around the world. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw…

Read more

hospital waste incinerator for the waste from hospital, lab, etc. Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry scrubber (smoke filter chamber) with reasonable project budget. For the cleaner emission require, we accept custom made wet scrubber for incinerator and this will be also our next working by focusing on emission technical.

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber     Temperature Monitoring Yes     Average ash residue (%) 3%     Thermostatic Device Yes   1000l diesel flue tank Venture gas scrubber Hydraulic Ram Feeding System Diesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Brand ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line Requirements.5) Compliance with applicable Ghanaian standards and regulations.Operational characteristics6) Two-stage incineration with dual chamber combustion7) Burn rate: 15 – 20 Kg/h8) Ability: not less than 130 L9) Concentrations of most pollutants in stack gases under detection limits10) Diesel fuel11) Electronic Machine control12) Easy to operate and minimal training13) Any accessory or dedicated Apparatus necessary to the proper functioning and utilization of the equipment included

small medical waste incinerator design with PLC( Programmable Logic Controller), Intelligent and Automatic operation. Set combuston time according to different waste material and incinerator stop combustion itself. Set temperature protection parameter, if the temperature overheat, incinerator stop combustion itself. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes…

Read more

HICLOVER is top supplier of medical waste incinerator china with hiclover brand and website www.hiclover.com. we design PLC control incinerator for better operation which is key point of the medical waste incinerator. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L…

Read more

110/141