Incinerateur
Basic Info. Export Markets:Global Additional Info. Trademark:clover Origin:China Production Capacity:1000 Sets Per Year Product Description Key Attributes: * All models with Dual combustion room. * Stainless Steel chimney/stack, long life. *based on order * High temperature, long life of incinerator. * Free or minimal installation onsite. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order New Design for pet animal cremation business. * One year warranty on incinerator and components in stock. Nanjing Clover Medical Technology Co., Ltd. is a major incinerator maker in China. We’re local manufacturer and one of the largest exporter of China. Burner room manufacturer, burner gas, burner gas, burner gas combustion efficiency, burner for medical, burner incinerator LPG, burner untuk incinerator, burners for clinical waste, Now, there are our incinerator product in the former Soviet Union area, Africa countries, Asia countries and…
Oil Pump Suction Line and Return Line on incinerator burner
on incinerator burner, there’s 1 oil pump and have two tube for Suction Line and Return Line.
hiclover 10kgs per hour incinerator
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Typical 20 kgs per feed Burning Rate Typical 10 kgs Each hour Burning Time Each Feed 2 hours Voltage 220V Fuel Diesel Petroleum Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour External Dimensions 100 x 100 x 160cm (mainbody) Internal Dimensions 50 x 50 x 80cm(Main Chamber) Waste combustion chamber 200Liters Article Combustion Chamber 100Liters Oil Tank Capacity 50 Liters Door Opening 35 x 35cm Chimney 3.0M Gross Weight 1000kgs Chamber Material Refractory Concrete Max. 126,000Kcal/Hr. Operation Technical Specifications Chamber fever Chamber Anti-Rate 8000C -10000C Residency time 13500C 0.5 Sec. Burning efficiency >98% Waste Lower Calorific Power HICLOVER – Medical Environmental 3000Kcal WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com Email: [email protected] Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Related medical waste heat…
Incinerator with Capacity of destruction in weight: 60 Kg/h.
Ability of destruction in weight: 60 Kg/h. It should be in a position to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes generated by hospitals, private clinics, labs, institutes, etc… Design Specification: Forms A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by simply controlling the gasification of waste. The incinerator must prevent the discharge of smoke and fine dust, (Smokeless) throughout the loadings. It should be able to decrease the volume of wastes from 98%. It should be in a position to hold emission in the next burn with gas residence of not less than 2 seconds. The incineration must be completely free of visible smoke in addition to offensive odours. The reduced volt electricity (L.C.P) of this waste will be 3,500 kcal/kg The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC Post combustion: 1100oC. The Internal diameter of…
Incinerator with Ease of Jealousy in weight: 60 Kg/h.
Ability of destruction in weight: 60 Kg/h. It should be able to work less 10 hours/day This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, labs, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by simply controlling the gasification of waste. The incinerator must prevent the discharge of smoke and dust that is fine, (Smokeless) during the loadings. It should have the ability to reduce the quantity of wastes from 98%. It should be able to hold emission in the next burn with gas residence of less than two seconds. The incineration should be completely free of visible smoke as well as offensive odours. The lower volt electricity (L.C.P) of the waste will be 3,500 kcal/kg The Temperatures of combustionMinimum will be 850oC and maximum 1400oC Post combustion: 1100oC. The Inner diameter of the Chimney: Ø…
Mobile Diesel Fired Incinerator in container
Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor c. Minimum Temperature of 1100 deg.C as per WHO guidelines. d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play c. Threezone monitoring of: i)Primary chamber ii) Secondary chamber iii) Hot hearth d. Digital display e. Burner on-off indication lights f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system c. Maximum noise at 1m x g0 decibels d. Exterior temperature 70 deg.C Max
Mobile Diesel Fired Incinerator in container
Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor c. Minimum Temperature of 1100 deg.C as per WHO guidelines. d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play c. Threezone monitoring of: i)Primary chamber ii) Secondary chamber iii) Hot hearth d. Digital display e. Burner on-off indication lights f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system c. Maximum noise at 1m x g0 decibels d. Exterior temperature 70 deg.C Max
a complete destruction of waste from various hospital services
Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste. -Chemical waste laboratory reagents, disinfectants -Expired drugs. -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards -UL,CE, ASME, ISA EURO emission standard 1.Medical waste incinerator Construction – CS plate shells, FB reinforcement, cast refractory linings, Insulation and 14 gage aluminum jacket. Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous Average fuel consumption – Very little as much as possible Control Type – PLC based operation Operating Temperature – Primary chamber 800oc ± 50 – Secondary Chamber 1050oc ± 50 Size of incinerator – Not more than 15mx7.20m Chimney – Ø630x25meter height and 7mm thick CS. Combustion efficiency- 99% Mode of waste handling- Semi-automatic via ram loader. Mode of ash handling – Semi-automatic via grate and ash trolley. Pollution control equipment- Dry settlement zone Doors- 1-waste charging door in primary chamber 1-clinker door in primary chamber 1-ash trolley access door in primary chamber 1-clean out door in secondary chamber Burner – 2- ignition burner in primary chamber 2- after burner in secondary chamber. Type- package mono block-fully automatic Type of burner operation- modulation control Forced draught fan- 1-primary air fan 1-secondary air fan Fuel storage tank – Capacity- 2500liter above ground – Material-6mm thick mild steel – 2-diesel pump, gate valve, safety valve, strainer Pipe, pressure gage, check valve, control board Level indicator. Etc Refractory/insulation thickness- not less than 225mm Ram loader capacity- 0.75m3 Electrical supply- 380v/3ph/50 Hz Finish and painting type- powder coated Audio/ visual alarm system- burner lockout, overload fault Electrical accessories- primary and secondary chamber temperature Controller/indicator, auto controls, electrical Control switches, push buttons, relays, contactors Thermocouples, burner sequence controllers, Timers, emergency stop and alarms.
a complete destruction of waste from various hospital services
Medical Waste Incinerator Purpose For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement. -Waste from health care activities -Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. -Pathological waste, human fragments, blood, fetus, all body fluids, human tissues. -Sculpts, needles, infusion sets, blades, glass -Pharmaceutical waste. -Chemical waste laboratory reagents, disinfectants -Expired drugs. -Low radiation radioactive element. Medical waste incinerator: – Ecological Requirement – No odor -No fume -Definitive treatment of waste Medical waste incinerator: – Manufacturing Standards -UL,CE, ASME, ISA EURO emission standard 1.Medical waste incinerator Construction – CS plate shells, FB reinforcement, cast refractory linings, Insulation and 14 gage aluminum jacket. Type of fuel – Oil fired (Diesel) Burning Capacity – 250kg/hr and moisture up to 80%. Duration -8-16/Continuous Average fuel consumption – Very little as much as possible Control Type – PLC based operation Operating Temperature – Primary chamber 800oc ± 50 – Secondary Chamber 1050oc ± 50 Size of incinerator – Not more than 15mx7.20m Chimney – Ø630x25meter height and 7mm thick CS. Combustion efficiency- 99% Mode of waste handling- Semi-automatic via ram loader. Mode of ash handling – Semi-automatic via grate and ash trolley. Pollution control equipment- Dry settlement zone Doors- 1-waste charging door in primary chamber 1-clinker door in primary chamber 1-ash trolley access door in primary chamber 1-clean out door in secondary chamber Burner – 2- ignition burner in primary chamber 2- after burner in secondary chamber. Type- package mono block-fully automatic Type of burner operation- modulation control Forced draught fan- 1-primary air fan 1-secondary air fan Fuel storage tank – Capacity- 2500liter above ground – Material-6mm thick mild steel – 2-diesel pump, gate valve, safety valve, strainer Pipe, pressure gage, check valve, control board Level indicator. Etc Refractory/insulation thickness- not less than 225mm Ram loader capacity- 0.75m3 Electrical supply- 380v/3ph/50 Hz Finish and painting type- powder coated Audio/ visual alarm system- burner lockout, overload fault Electrical accessories- primary and secondary chamber temperature Controller/indicator, auto controls, electrical Control switches, push buttons, relays, contactors Thermocouples, burner sequence controllers, Timers, emergency stop and alarms.